A bath under the raised house
The exemption ends where a bathroom adds to the building: a new bath built into the ground level beneath a raised structure is an enclosure below the lowest floor, the third condition’s exact case, and a bath added in a bump-out reaches past the existing foundation and needs new foundation of its own, which fails the first two. Either one leaves the exemption behind and is read against the coastal code instead.
More on under the house
For the bath beneath a raised house, the code then asks how high the enclosure sits. In a Zone A or Zone V flood area, the code holds an enclosure below the flood elevation set under ASCE 24 or by the city to parking, an entry and storage, so no bathroom goes there. Between that elevation and the 100-year storm elevation, toilet rooms and bathrooms are among the allowed uses, while rooms for living, sleeping or cooking are not.
Condition three also catches a rinse shower walled in beneath a raised deck, since the walls make an enclosure below the deck; left open to the air, the same shower adds none.
So for an owner who wants a bathroom at ground level, the first question is height, not finish. A bath that already exists upstairs can be rebuilt around a new walk-in shower outside the coastal code, while a new one beneath the house is an allowed use only in an enclosure above that flood elevation, or one dry floodproofed to it.